Vendor Siemens First view 2022-10-11
Product Simatic s7-1500 Cpu 15pro-2 Firmware Last view 2022-12-13
Version * Type Os
Update *  
Edition *  
Language *  
Sofware Edition *  
Target Software *  
Target Hardware *  
Other *  
 
CPE Product cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware

Activity : Overall

Related : CVE

  Date Alert Description
4.9 2022-12-13 CVE-2021-44695

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

5.5 2022-12-13 CVE-2021-44694

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

4.9 2022-12-13 CVE-2021-44693

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

7.5 2022-12-13 CVE-2021-40365

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

7.8 2022-10-11 CVE-2022-38465

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.

This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.

CWE : Common Weakness Enumeration

%idName
50% (1) CWE-522 Insufficiently Protected Credentials
50% (1) CWE-20 Improper Input Validation