Summary
Title HP Insight Diagnostics Online Edition, Remote Cross Site Scripting (XSS)
Informations
Name HPSBMA02571 SSRT100034 First vendor Publication 2010-08-30
Vendor HP Last vendor Modification 2010-08-30
Severity (Vendor) N/A Revision 1

Security-Database Scoring CVSS v3

Cvss vector : N/A
Overall CVSS Score NA
Base Score NA Environmental Score NA
impact SubScore NA Temporal Score NA
Exploitabality Sub Score NA
 
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:N/AC:M/Au:N/C:N/I:P/A:N)
Cvss Base Score 4.3 Attack Range Network
Cvss Impact Score 2.9 Attack Complexity Medium
Cvss Expoit Score 8.6 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

A potential security vulnerability has been identified with HP Insight Diagnostics Online Edition running on Linux. The vulnerability could be exploited remotely resulting in cross site scripting (XSS).

Original Source

Url : http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02492472

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-79 Failure to Preserve Web Page Structure ('Cross-site Scripting') (CWE/SANS Top 25)

CPE : Common Platform Enumeration

TypeDescriptionCount
Application 150

OpenVAS Exploits

Date Description
2010-12-21 Name : HP SMH Insight Diagnostics Multiple Cross Site Scripting Vulnerabilities
File : nvt/gb_hp_smh_insight_diag_mult_xss_vuln.nasl

Open Source Vulnerability Database (OSVDB)

Id Description
74993 HP Insight Diagnostics Online Edition on Linux custom.php testmode Parameter XSS

HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'testmode' parameter upon submission to the custom.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server.
74992 HP Insight Diagnostics Online Edition on Linux globals.php tabpage Parameter XSS

HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'tabpage' parameter upon submission to the globals.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server.
74991 HP Insight Diagnostics Online Edition on Linux survey.php category Parameter XSS

HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'category' parameter upon submission to the survey.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server.
74990 HP Insight Diagnostics Online Edition on Linux idstatusframe.php Multiple Par...

HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'pid' and 'cfg' parameters upon submission to the idstatusframe.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server.
67748 HP Insight Diagnostics Online Edition on Linux parameters.php device Paramete...

HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'device' parameter upon submission to the parameters.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server.

Snort® IPS/IDS

Date Description
2014-01-10 HP Insight Diagnostics XSS attempt
RuleID : 21314 - Revision : 4 - Type : SERVER-WEBAPP