Executive Summary
This Alert is flagged as TOP 25 Common Weakness Enumeration from CWE/SANS. For more information, you can read this.
Informations | |||
---|---|---|---|
Name | CVE-2010-3003 | First vendor Publication | 2010-09-10 |
Vendor | Cve | Last vendor Modification | 2019-10-09 |
Security-Database Scoring CVSS v3
Cvss vector : N/A | |||
---|---|---|---|
Overall CVSS Score | NA | ||
Base Score | NA | Environmental Score | NA |
impact SubScore | NA | Temporal Score | NA |
Exploitabality Sub Score | NA | ||
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : (AV:N/AC:M/Au:N/C:N/I:P/A:N) | |||
---|---|---|---|
Cvss Base Score | 4.3 | Attack Range | Network |
Cvss Impact Score | 2.9 | Attack Complexity | Medium |
Cvss Expoit Score | 8.6 | Authentication | None Required |
Calculate full CVSS 2.0 Vectors scores |
Detail
Cross-site scripting (XSS) vulnerability in HP Insight Diagnostics Online Edition before 8.5.0-11 on Linux allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2010-3003 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-79 | Failure to Preserve Web Page Structure ('Cross-site Scripting') (CWE/SANS Top 25) |
CPE : Common Platform Enumeration
OpenVAS Exploits
Date | Description |
---|---|
2010-12-21 | Name : HP SMH Insight Diagnostics Multiple Cross Site Scripting Vulnerabilities File : nvt/gb_hp_smh_insight_diag_mult_xss_vuln.nasl |
Open Source Vulnerability Database (OSVDB)
Id | Description |
---|---|
74993 | HP Insight Diagnostics Online Edition on Linux custom.php testmode Parameter XSS HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'testmode' parameter upon submission to the custom.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server. |
74992 | HP Insight Diagnostics Online Edition on Linux globals.php tabpage Parameter XSS HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'tabpage' parameter upon submission to the globals.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server. |
74991 | HP Insight Diagnostics Online Edition on Linux survey.php category Parameter XSS HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'category' parameter upon submission to the survey.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server. |
74990 | HP Insight Diagnostics Online Edition on Linux idstatusframe.php Multiple Par... HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'pid' and 'cfg' parameters upon submission to the idstatusframe.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server. |
67748 | HP Insight Diagnostics Online Edition on Linux parameters.php device Paramete... HP Insight Diagnostics Online Edition on Linux contains a flaw that allows a remote cross-site scripting (XSS) attack. This flaw exists because the application does not validate the 'device' parameter upon submission to the parameters.php script. This may allow a user to create a specially crafted URL that would execute arbitrary script code in a user's browser within the trust relationship between their browser and the server. |
Snort® IPS/IDS
Date | Description |
---|---|
2014-01-10 | HP Insight Diagnostics XSS attempt RuleID : 21314 - Revision : 4 - Type : SERVER-WEBAPP |
Sources (Detail)
Alert History
Date | Informations |
---|---|
2021-05-04 12:11:54 |
|
2021-04-22 01:12:35 |
|
2020-05-23 01:42:28 |
|
2020-05-23 00:26:16 |
|
2019-10-10 05:19:26 |
|
2018-11-02 12:02:36 |
|
2016-04-26 20:01:17 |
|
2014-01-19 21:27:03 |
|
2013-05-10 23:30:26 |
|