Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2017-3860 | First vendor Publication | 2017-04-20 |
Vendor | Cve | Last vendor Modification | 2024-11-21 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H | |||
---|---|---|---|
Overall CVSS Score | 8.6 | ||
Base Score | 8.6 | Environmental Score | 8.6 |
impact SubScore | 4 | Temporal Score | 8.6 |
Exploitabality Sub Score | 3.9 | ||
Attack Vector | Network | Attack Complexity | Low |
Privileges Required | None | User Interaction | None |
Scope | Changed | Confidentiality Impact | None |
Integrity Impact | None | Availability Impact | High |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : (AV:N/AC:L/Au:N/C:N/I:N/A:C) | |||
---|---|---|---|
Cvss Base Score | 7.8 | Attack Range | Network |
Cvss Impact Score | 6.9 | Attack Complexity | Low |
Cvss Expoit Score | 10 | Authentication | None Required |
Calculate full CVSS 2.0 Vectors scores |
Detail
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCur29331. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-3860 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-119 | Failure to Constrain Operations within the Bounds of a Memory Buffer |
CPE : Common Platform Enumeration
Snort® IPS/IDS
Date | Description |
---|---|
2020-12-05 | Cisco IOS EnergyWise out of bounds read attempt RuleID : 53472 - Revision : 1 - Type : SERVER-OTHER |
2020-12-05 | Cisco IOS EnergyWise integer underflow attempt RuleID : 53471 - Revision : 1 - Type : SERVER-OTHER |
2020-12-05 | Cisco IOS EnergyWise heap buffer overflow attempt RuleID : 53470 - Revision : 1 - Type : SERVER-OTHER |
Nessus® Vulnerability Scanner
Date | Description |
---|---|
2017-04-26 | Name : The remote device is missing a vendor-supplied security patch. File : cisco-sa-20170419-energywise-ios.nasl - Type : ACT_GATHER_INFO |
2017-04-26 | Name : The remote device is missing a vendor-supplied security patch. File : cisco-sa-20170419-energywise-iosxe.nasl - Type : ACT_GATHER_INFO |
Sources (Detail)
Source | Url |
---|
Alert History
Date | Informations |
---|---|
2024-11-28 13:07:01 |
|
2021-05-04 13:01:40 |
|
2021-04-22 02:15:09 |
|
2020-12-05 21:23:46 |
|
2020-05-23 01:00:32 |
|
2017-07-11 12:05:30 |
|
2017-04-28 21:23:17 |
|
2017-04-27 13:24:51 |
|
2017-04-22 09:25:40 |
|
2017-04-21 05:22:27 |
|