Executive Summary



This Alert is flagged as TOP 25 Common Weakness Enumeration from CWE/SANS. For more information, you can read this.
Summary
Title Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge cross-site scripting vulnerability
Informations
Name VU#882619 First vendor Publication 2009-02-05
Vendor VU-CERT Last vendor Modification 2009-02-05
Severity (Vendor) N/A Revision M

Security-Database Scoring CVSS v3

Cvss vector : N/A
Overall CVSS Score NA
Base Score NA Environmental Score NA
impact SubScore NA Temporal Score NA
Exploitabality Sub Score NA
 
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:N/AC:M/Au:N/C:N/I:P/A:N)
Cvss Base Score 4.3 Attack Range Network
Cvss Impact Score 2.9 Attack Complexity Medium
Cvss Expoit Score 8.6 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

Vulnerability Note VU#882619

Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge cross-site scripting vulnerability

Overview

The Rockwell ControlLogix 1756-ENBT/A EtherNet/IP Bridge web interface contains a cross-site scripting vulnerability that may allow an attacker to spoof data or redirect end user's to other sites.

I. Description

The Rockwell Logix Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge uses a web interface to display log files and status information. This web interface contains multiple cross-site scripting vulnerabilities. To exploit these issues, an attacker would need to convince an operator to open on a specially crafted URL.

II. Impact

An attacker may be able to execute arbitrary javascript in an operator's browser. This script could be used to spoof data or redirect an operator's web browser to other sites.

III. Solution

See Rockwell's vendor statement for information about obtaining fixed software. Until updated firmware is available, the below workarounds will mitigate this vulnerability.

Do not allow remote access

If no Internet connectivity is allowed (including access through email, proxies or firewalls) to the operator's computer, an attacker will not be able to remotely exploit this issue. See Rockwell's Reference Architectures for Manufacturing site for more information about secure network configurations.

Systems Affected

VendorStatusDate NotifiedDate Updated
Rockwell AutomationVulnerable2009-02-05

References


http://www.ab.com/networks/architectures.html
http://en.wikipedia.org/w/index.php?title=Cross-site_scripting&oldid=268497783

Credit

Thanks to Daniel Peck of Digital Bond, Inc. for reporting this issue.

This document was written by Ryan Giobbi.

Other Information

Date Public:2009-02-01
Date First Published:2009-02-05
Date Last Updated:2009-02-05
CERT Advisory: 
CVE-ID(s): 
NVD-ID(s): 
US-CERT Technical Alerts: 
Metric:0.05
Document Revision:56

Original Source

Url : http://www.kb.cert.org/vuls/id/882619

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-79 Failure to Preserve Web Page Structure ('Cross-site Scripting') (CWE/SANS Top 25)

CPE : Common Platform Enumeration

TypeDescriptionCount
Application 1

Open Source Vulnerability Database (OSVDB)

Id Description
54116 Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module Web In...