Executive Summary

Informations
Name CVE-2023-29131 First vendor Publication 2023-07-11
Vendor Cve Last vendor Modification 2024-11-21

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Overall CVSS Score 10
Base Score 10 Environmental Score 10
impact SubScore 6 Temporal Score 10
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Changed Confidentiality Impact High
Integrity Impact High Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector :
Cvss Base Score N/A Attack Range N/A
Cvss Impact Score N/A Attack Complexity N/A
Cvss Expoit Score N/A Authentication N/A
Calculate full CVSS 2.0 Vectors scores

Detail

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2023-29131

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-276 Incorrect Default Permissions

CPE : Common Platform Enumeration

TypeDescriptionCount
Application 1

Sources (Detail)

https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf
Source Url

Alert History

If you want to see full details history, please login or register.
0
1
2
Date Informations
2024-11-28 14:24:20
  • Multiple Updates
2023-07-18 21:27:19
  • Multiple Updates
2023-07-11 17:27:16
  • First insertion