Informations
Name CVE-2022-36559 First vendor Publication 2022-08-29
Vendor Cve Last vendor Modification 2024-11-21

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Overall CVSS Score 9.8
Base Score 9.8 Environmental Score 9.8
impact SubScore 5.9 Temporal Score 9.8
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact High
Integrity Impact High Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector :
Cvss Base Score N/A Attack Range N/A
Cvss Impact Score N/A Attack Complexity N/A
Cvss Expoit Score N/A Authentication N/A
Calculate full CVSS 2.0 Vectors scores

Detail

Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-36559

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-77 Improper Sanitization of Special Elements used in a Command ('Command Injection')

Sources (Detail)

https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e
https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/