Executive Summary

Informations
Name CVE-2022-31807 First vendor Publication 2025-05-23
Vendor Cve Last vendor Modification 2025-05-23

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Overall CVSS Score 6.2
Base Score 6.2 Environmental Score 6.2
impact SubScore 3.6 Temporal Score 6.2
Exploitabality Sub Score 2.5
 
Attack Vector Local Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact None
Integrity Impact High Availability Impact None
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector :
Cvss Base Score N/A Attack Range N/A
Cvss Impact Score N/A Attack Complexity N/A
Cvss Expoit Score N/A Authentication N/A
Calculate full CVSS 2.0 Vectors scores

Detail

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions), SiPass integrated ACC-AP (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-31807

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-347 Improper Verification of Cryptographic Signature

Sources (Detail)

https://cert-portal.siemens.com/productcert/html/ssa-367714.html