Executive Summary

Informations
Name CVE-2022-1368 First vendor Publication 2022-09-06
Vendor Cve Last vendor Modification 2024-11-21

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Overall CVSS Score 9.8
Base Score 9.8 Environmental Score 9.8
impact SubScore 5.9 Temporal Score 9.8
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact High
Integrity Impact High Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector :
Cvss Base Score N/A Attack Range N/A
Cvss Impact Score N/A Attack Complexity N/A
Cvss Expoit Score N/A Authentication N/A
Calculate full CVSS 2.0 Vectors scores

Detail

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-1368

Sources (Detail)

https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03
Source Url

Alert History

If you want to see full details history, please login or register.
0
1
2
3
Date Informations
2024-11-28 14:04:42
  • Multiple Updates
2022-09-12 17:27:10
  • Multiple Updates
2022-09-07 17:27:10
  • Multiple Updates
2022-09-07 05:27:10
  • First insertion