Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2021-27384 | First vendor Publication | 2021-05-12 |
Vendor | Cve | Last vendor Modification | 2021-12-16 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | |||
---|---|---|---|
Overall CVSS Score | 9.8 | ||
Base Score | 9.8 | Environmental Score | 9.8 |
impact SubScore | 5.9 | Temporal Score | 9.8 |
Exploitabality Sub Score | 3.9 | ||
Attack Vector | Network | Attack Complexity | Low |
Privileges Required | None | User Interaction | None |
Scope | Unchanged | Confidentiality Impact | High |
Integrity Impact | High | Availability Impact | High |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : (AV:N/AC:L/Au:N/C:P/I:P/A:P) | |||
---|---|---|---|
Cvss Base Score | 7.5 | Attack Range | Network |
Cvss Impact Score | 6.4 | Attack Complexity | Low |
Cvss Expoit Score | 10 | Authentication | None Required |
Calculate full CVSS 2.0 Vectors scores |
Detail
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-27384 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-788 | Access of Memory Location After End of Buffer (CWE/SANS Top 25) |
CPE : Common Platform Enumeration
Sources (Detail)
Source | Url |
---|---|
MISC | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 |
Alert History
Date | Informations |
---|---|
2021-12-16 21:23:14 |
|
2021-10-12 17:23:04 |
|
2021-09-14 17:23:03 |
|
2021-08-19 12:43:37 |
|
2021-08-10 17:22:55 |
|
2021-05-21 21:23:15 |
|
2021-05-18 00:22:52 |
|
2021-05-12 21:23:12 |
|