Executive Summary



This Alert is flagged as TOP 25 Common Weakness Enumeration from CWE/SANS. For more information, you can read this.
Informations
Name CVE-2019-3929 First vendor Publication 2019-04-30
Vendor Cve Last vendor Modification 2025-02-07

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Overall CVSS Score 9.8
Base Score 9.8 Environmental Score 9.8
impact SubScore 5.9 Temporal Score 9.8
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact High
Integrity Impact High Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:N/AC:L/Au:N/C:C/I:C/A:C)
Cvss Base Score 10 Attack Range Network
Cvss Impact Score 10 Attack Complexity Low
Cvss Expoit Score 10 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-3929

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-78 Improper Sanitization of Special Elements used in an OS Command ('OS Command Injection') (CWE/SANS Top 25)

CPE : Common Platform Enumeration

TypeDescriptionCount
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1
Os 1

Snort® IPS/IDS

Date Description
2019-07-09 Crestron AM platform command injection attempt
RuleID : 50326 - Revision : 1 - Type : SERVER-WEBAPP
2019-07-09 Crestron AM platform command injection attempt
RuleID : 50325 - Revision : 1 - Type : SERVER-WEBAPP
2019-07-09 Crestron AM platform command injection attempt
RuleID : 50324 - Revision : 1 - Type : SERVER-WEBAPP
2019-07-09 Crestron AM platform command injection attempt
RuleID : 50323 - Revision : 1 - Type : SERVER-WEBAPP

Sources (Detail)

http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Plat...
http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi...
https://www.exploit-db.com/exploits/46786/
https://www.tenable.com/security/research/tra-2019-20
Source Url

Alert History

If you want to see full details history, please login or register.
0
1
2
3
4
5
6
7
8
9
Date Informations
2025-02-07 17:21:17
  • Multiple Updates
2025-02-07 00:21:29
  • Multiple Updates
2024-11-28 13:32:13
  • Multiple Updates
2020-10-17 00:22:51
  • Multiple Updates
2020-05-23 13:17:11
  • Multiple Updates
2020-05-23 02:30:02
  • Multiple Updates
2019-05-04 09:19:18
  • Multiple Updates
2019-05-04 00:18:58
  • Multiple Updates
2019-05-03 13:19:12
  • Multiple Updates
2019-05-01 05:19:08
  • First insertion