Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2017-12235 | First vendor Publication | 2017-09-28 |
Vendor | Cve | Last vendor Modification | 2025-01-27 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | |||
---|---|---|---|
Overall CVSS Score | 7.5 | ||
Base Score | 7.5 | Environmental Score | 7.5 |
impact SubScore | 3.6 | Temporal Score | 7.5 |
Exploitabality Sub Score | 3.9 | ||
Attack Vector | Network | Attack Complexity | Low |
Privileges Required | None | User Interaction | None |
Scope | Unchanged | Confidentiality Impact | None |
Integrity Impact | None | Availability Impact | High |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : (AV:N/AC:L/Au:N/C:N/I:N/A:C) | |||
---|---|---|---|
Cvss Base Score | 7.8 | Attack Range | Network |
Cvss Impact Score | 6.9 | Attack Complexity | Low |
Cvss Expoit Score | 10 | Authentication | None Required |
Calculate full CVSS 2.0 Vectors scores |
Detail
A vulnerability in the implementation of the PROFINET Discovery and Configuration Protocol (PN-DCP) for Cisco IOS 12.2 through 15.6 could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper parsing of ingress PN-DCP Identify Request packets destined to an affected device. An attacker could exploit this vulnerability by sending a crafted PN-DCP Identify Request packet to an affected device and then continuing to send normal PN-DCP Identify Request packets to the device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition. This vulnerability affects Cisco devices that are configured to process PROFINET messages. Beginning with Cisco IOS Software Release 12.2(52)SE, PROFINET is enabled by default on all the base switch module and expansion-unit Ethernet ports. Cisco Bug IDs: CSCuz47179. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-12235 |
CPE : Common Platform Enumeration
Nessus® Vulnerability Scanner
Date | Description |
---|---|
2017-10-05 | Name : The remote device is missing a vendor-supplied security patch. File : cisco-sa-20170927-profinet.nasl - Type : ACT_GATHER_INFO |
Sources (Detail)
Source | Url |
---|
Alert History
Date | Informations |
---|---|
2025-01-28 00:21:11 |
|
2024-11-28 13:02:26 |
|
2024-10-04 01:42:15 |
|
2024-10-03 01:42:49 |
|
2024-07-24 17:27:36 |
|
2024-07-16 21:27:42 |
|
2021-05-04 12:58:04 |
|
2021-04-22 02:11:19 |
|
2020-05-23 00:55:26 |
|
2019-10-10 05:19:42 |
|
2017-10-07 00:22:47 |
|
2017-10-06 13:25:09 |
|
2017-09-30 09:23:38 |
|
2017-09-29 09:24:19 |
|