Executive Summary

Informations
Name CVE-2017-10605 First vendor Publication 2017-07-17
Vendor Cve Last vendor Modification 2019-10-09

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Overall CVSS Score 7.5
Base Score 7.5 Environmental Score 7.5
impact SubScore 3.6 Temporal Score 7.5
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact None
Integrity Impact None Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:N/AC:L/Au:N/C:N/I:N/A:P)
Cvss Base Score 5 Attack Range Network
Cvss Impact Score 2.9 Attack Complexity Low
Cvss Expoit Score 10 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-10605

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-20 Improper Input Validation

CPE : Common Platform Enumeration

TypeDescriptionCount
Os 34

Nessus® Vulnerability Scanner

Date Description
2017-08-23 Name : The remote device is missing a vendor-supplied security patch.
File : juniper_jsa10789.nasl - Type : ACT_GATHER_INFO

Sources (Detail)

Source Url
CONFIRM https://kb.juniper.net/JSA10789
SECTRACK http://www.securitytracker.com/id/1038891

Alert History

If you want to see full details history, please login or register.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Date Informations
2024-02-02 01:43:16
  • Multiple Updates
2024-02-01 12:12:11
  • Multiple Updates
2023-09-05 12:41:17
  • Multiple Updates
2023-09-05 01:11:55
  • Multiple Updates
2023-09-02 12:41:04
  • Multiple Updates
2023-09-02 01:12:12
  • Multiple Updates
2023-08-12 12:44:32
  • Multiple Updates
2023-08-12 01:11:41
  • Multiple Updates
2023-08-11 12:39:11
  • Multiple Updates
2023-08-11 01:12:01
  • Multiple Updates
2023-08-06 12:37:54
  • Multiple Updates
2023-08-06 01:11:40
  • Multiple Updates
2023-08-04 12:38:04
  • Multiple Updates
2023-08-04 01:11:44
  • Multiple Updates
2023-07-14 12:38:05
  • Multiple Updates
2023-07-14 01:11:43
  • Multiple Updates
2023-03-29 01:39:52
  • Multiple Updates
2023-03-28 12:12:01
  • Multiple Updates
2022-10-11 12:34:00
  • Multiple Updates
2022-10-11 01:11:39
  • Multiple Updates
2020-05-23 00:54:45
  • Multiple Updates
2019-10-10 05:19:39
  • Multiple Updates
2019-04-16 12:07:56
  • Multiple Updates
2017-08-24 13:25:06
  • Multiple Updates
2017-07-27 21:23:16
  • Multiple Updates
2017-07-22 09:22:24
  • Multiple Updates
2017-07-18 09:23:24
  • Multiple Updates
2017-07-17 21:22:59
  • Multiple Updates
2017-07-17 17:22:23
  • First insertion