Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2024-21917 | First vendor Publication | 2024-01-31 |
Vendor | Cve | Last vendor Modification | 2024-02-08 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N | |||
---|---|---|---|
Overall CVSS Score | 9.1 | ||
Base Score | 9.1 | Environmental Score | 9.1 |
impact SubScore | 5.2 | Temporal Score | 9.1 |
Exploitabality Sub Score | 3.9 | ||
Attack Vector | Network | Attack Complexity | Low |
Privileges Required | None | User Interaction | None |
Scope | Unchanged | Confidentiality Impact | High |
Integrity Impact | High | Availability Impact | None |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : | |||
---|---|---|---|
Cvss Base Score | N/A | Attack Range | N/A |
Cvss Impact Score | N/A | Attack Complexity | N/A |
Cvss Expoit Score | N/A | Authentication | N/A |
Calculate full CVSS 2.0 Vectors scores |
Detail
A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of digital signing between the FTSP service token and directory.  If exploited, a malicious user could potentially retrieve user information and modify settings without any authentication. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2024-21917 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-347 | Improper Verification of Cryptographic Signature |
CPE : Common Platform Enumeration
Sources (Detail)
Source | Url |
---|
Alert History
Date | Informations |
---|---|
2024-02-08 09:27:30 |
|
2024-02-01 00:27:23 |
|