Executive Summary

Informations
Name CVE-2020-12834 First vendor Publication 2020-05-15
Vendor Cve Last vendor Modification 2020-05-21

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Overall CVSS Score 9.8
Base Score 9.8 Environmental Score 9.8
impact SubScore 5.9 Temporal Score 9.8
Exploitabality Sub Score 3.9
 
Attack Vector Network Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact High
Integrity Impact High Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:N/AC:L/Au:N/C:P/I:P/A:P)
Cvss Base Score 7.5 Attack Range Network
Cvss Impact Score 6.4 Attack Complexity Low
Cvss Expoit Score 10 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-12834

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-276 Incorrect Default Permissions

CPE : Common Platform Enumeration

TypeDescriptionCount
Os 8
Os 14

Sources (Detail)

Source Url
MISC https://psytester.github.io/CVE-2020-12834/

Alert History

If you want to see full details history, please login or register.
0
Date Informations
2020-05-23 02:35:52
  • First insertion