Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2019-12690 | First vendor Publication | 2019-10-02 |
Vendor | Cve | Last vendor Modification | 2019-10-10 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | |||
---|---|---|---|
Overall CVSS Score | 7.2 | ||
Base Score | 7.2 | Environmental Score | 7.2 |
impact SubScore | 5.9 | Temporal Score | 7.2 |
Exploitabality Sub Score | 1.2 | ||
Attack Vector | Network | Attack Complexity | Low |
Privileges Required | High | User Interaction | None |
Scope | Unchanged | Confidentiality Impact | High |
Integrity Impact | High | Availability Impact | High |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : (AV:N/AC:L/Au:S/C:C/I:C/A:C) | |||
---|---|---|---|
Cvss Base Score | 9 | Attack Range | Network |
Cvss Impact Score | 10 | Attack Complexity | Low |
Cvss Expoit Score | 8 | Authentication | Requires single instance |
Calculate full CVSS 2.0 Vectors scores |
Detail
A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with the privileges of the root user of the underlying operating system. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input in the web UI. A successful exploit could allow an attacker to execute arbitrary commands on the device with full root privileges. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-12690 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-78 | Improper Sanitization of Special Elements used in an OS Command ('OS Command Injection') (CWE/SANS Top 25) |
CPE : Common Platform Enumeration
Snort® IPS/IDS
Date | Description |
---|---|
2020-12-05 | Cisco Firepower Management Center command injection attempt RuleID : 51719 - Revision : 1 - Type : SERVER-WEBAPP |
2020-12-05 | Cisco Firepower Management Center command injection attempt RuleID : 51718 - Revision : 1 - Type : SERVER-WEBAPP |
2020-12-05 | Cisco Firepower Management Center command injection attempt RuleID : 51717 - Revision : 1 - Type : SERVER-WEBAPP |
2020-12-05 | Cisco Firepower Management Center command injection attempt RuleID : 51716 - Revision : 1 - Type : SERVER-WEBAPP |
Sources (Detail)
Source | Url |
---|---|
CISCO | https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-s... |
Alert History
Date | Informations |
---|---|
2022-11-22 12:44:46 |
|
2022-11-19 12:43:56 |
|
2021-10-30 01:35:02 |
|
2021-05-05 01:33:22 |
|
2021-05-04 13:24:12 |
|
2021-04-22 02:39:07 |
|
2021-01-20 01:27:35 |
|
2020-12-05 21:23:47 |
|
2020-05-24 01:27:33 |
|
2020-05-23 02:22:18 |
|
2019-10-11 00:20:51 |
|
2019-10-03 00:19:39 |
|