Executive Summary

Informations
Name CVE-2017-2681 First vendor Publication 2017-05-11
Vendor Cve Last vendor Modification 2022-04-12

Security-Database Scoring CVSS v3

Cvss vector : CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Overall CVSS Score 6.5
Base Score 6.5 Environmental Score 6.5
impact SubScore 3.6 Temporal Score 6.5
Exploitabality Sub Score 2.8
 
Attack Vector Adjacent Attack Complexity Low
Privileges Required None User Interaction None
Scope Unchanged Confidentiality Impact None
Integrity Impact None Availability Impact High
Calculate full CVSS 3.0 Vectors scores

Security-Database Scoring CVSS v2

Cvss vector : (AV:A/AC:L/Au:N/C:N/I:N/A:C)
Cvss Base Score 6.1 Attack Range Adjacent network
Cvss Impact Score 6.9 Attack Complexity Low
Cvss Expoit Score 6.5 Authentication None Required
Calculate full CVSS 2.0 Vectors scores

Detail

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices.

Original Source

Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-2681

CWE : Common Weakness Enumeration

% Id Name
100 % CWE-400 Uncontrolled Resource Consumption ('Resource Exhaustion')

CPE : Common Platform Enumeration

TypeDescriptionCount
Hardware 2
Hardware 1
Hardware 2
Os 3
Os 2
Os 2
Os 1
Os 1
Os 1
Os 3
Os 3
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 1
Os 1
Os 2
Os 1
Os 1
Os 2
Os 2
Os 2
Os 2
Os 2
Os 1
Os 2
Os 2
Os 2
Os 1
Os 2
Os 2
Os 2
Os 1
Os 1
Os 2
Os 1
Os 1
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 2
Os 4
Os 2
Os 2
Os 4
Os 1
Os 1
Os 1
Os 1
Os 1
Os 2
Os 2
Os 2
Os 3
Os 3
Os 2
Os 1
Os 3
Os 3
Os 2
Os 3
Os 2
Os 1
Os 5
Os 5
Os 2
Os 1
Os 1
Os 2
Os 3
Os 2

Sources (Detail)

Source Url
BID http://www.securityfocus.com/bid/98369
CONFIRM https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf
MISC https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf
SECTRACK http://www.securitytracker.com/id/1038463

Alert History

If you want to see full details history, please login or register.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Date Informations
2022-04-13 00:23:42
  • Multiple Updates
2022-02-10 12:28:33
  • Multiple Updates
2021-04-22 02:15:26
  • Multiple Updates
2021-03-26 12:22:04
  • Multiple Updates
2020-09-29 21:23:09
  • Multiple Updates
2020-07-14 21:22:59
  • Multiple Updates
2020-05-24 01:21:39
  • Multiple Updates
2020-05-23 02:05:49
  • Multiple Updates
2020-05-23 00:59:55
  • Multiple Updates
2018-07-04 12:02:17
  • Multiple Updates
2018-04-21 12:04:27
  • Multiple Updates
2018-03-01 13:20:58
  • Multiple Updates
2018-02-24 09:20:09
  • Multiple Updates
2018-01-25 09:21:50
  • Multiple Updates
2018-01-19 09:22:21
  • Multiple Updates
2018-01-12 12:04:16
  • Multiple Updates
2017-12-30 09:22:06
  • Multiple Updates
2017-07-08 09:24:05
  • Multiple Updates
2017-06-17 09:22:55
  • Multiple Updates
2017-05-23 09:22:44
  • Multiple Updates
2017-05-11 17:23:02
  • First insertion