Vendor Juniper First view 2020-07-17
Product Junos Os Evolved Last view 2021-04-22
Version 19.3 Type Os
Update r2  
Edition *  
Language *  
Sofware Edition *  
Target Software *  
Target Hardware *  
Other *  
 
CPE Product cpe:2.3:o:juniper:junos_os_evolved

Activity : Overall

Related : CVE

  Date Alert Description
7.5 2021-04-22 CVE-2021-0264

A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulletin TSB17931 (login required). This issue affects: Juniper Networks Junos OS on MX Series: 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2. Juniper Networks Junos OS Evolved on PTX10003, PTX10008: All versions prior to 20.4R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1.

7.4 2021-04-22 CVE-2021-0259

Due to a vulnerability in DDoS protection in Juniper Networks Junos OS and Junos OS Evolved on QFX5K Series switches in a VXLAN configuration, instability might be experienced in the underlay network as a consequence of exceeding the default ddos-protection aggregate threshold. If an attacker on a client device on the overlay network sends a high volume of specific, legitimate traffic in the overlay network, due to an improperly detected DDoS violation, the leaf might not process certain L2 traffic, sent by spines in the underlay network. Continued receipt and processing of the high volume traffic will sustain the Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on QFX5K Series: 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R2-S8, 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R1-S2, 20.3R2. Juniper Networks Junos OS Evolved on QFX5220: All versions prior to 20.3R2-EVO.

6.5 2021-04-22 CVE-2021-0236

Due to an improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved the Routing Protocol Daemon (RPD) service, upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, crashes and restarts causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects only Multiprotocol BGP (MP-BGP) VPNv6 FlowSpec deployments. This issue affects: Juniper Networks Junos OS: 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R2-S2, 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. Juniper Networks Junos OS Evolved: All versions after 18.4R1-EVO prior to 20.3R2-EVO. This issue does not affect: Juniper Networks Junos OS versions prior to 18.4R1. Juniper Networks Junos OS Evolved versions prior to 18.4R1-EVO.

5.8 2021-04-22 CVE-2021-0225

An Improper Check for Unusual or Exceptional Conditions in Juniper Networks Junos OS Evolved may cause the stateless firewall filter configuration which uses the action 'policer' in certain combinations with other options to not take effect. An administrator can use the following CLI command to see the failures with filter configuration: user@device> show log kfirewall-agent.log | match ERROR Jul 23 14:16:03 ERROR: filter not supported This issue affects Juniper Networks Junos OS Evolved: Versions 19.1R1-EVO and above prior to 20.3R1-S2-EVO, 20.3R2-EVO. This issue does not affect Juniper Networks Junos OS.

7.5 2020-07-17 CVE-2020-1644

On Juniper Networks Junos OS and Junos OS Evolved devices, the receipt of a specific BGP UPDATE packet causes an internal counter to be incremented incorrectly, which over time can lead to the routing protocols process (RPD) crash and restart. This issue affects both IBGP and EBGP multihop deployment in IPv4 or IPv6 network. This issue affects: Juniper Networks Junos OS: 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.2X75 versions prior to 18.2X75-D13, 18.2X75-D411.1, 18.2X75-D420.18, 18.2X75-D52.3, 18.2X75-D60; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS Evolved: any releases prior to 20.1R2-EVO. This issue does not affect Juniper Networks Junos OS releases prior to 17.3R1.

CWE : Common Weakness Enumeration

%idName
40% (2) CWE-755 Improper Handling of Exceptional Conditions
40% (2) CWE-754 Improper Check for Unusual or Exceptional Conditions
20% (1) CWE-20 Improper Input Validation