This CPE summary could be partial or incomplete. Please contact us for a detailed listing.

Summary

Detail
Vendor Konicaminolta First view 2022-01-04
Product Bizhub 368 Firmware Last view 2022-05-16
Version Type Os
Update  
Edition  
Language  
Sofware Edition  
Target Software  
Target Hardware  
Other  

Activity : Overall

COMMON PLATFORM ENUMERATION: Repartition per Version

CPE Name Affected CVE
cpe:2.3:o:konicaminolta:bizhub_368_firmware:*:*:*:*:*:*:*:* 8
cpe:2.3:o:konicaminolta:bizhub_368_firmware:-:*:*:*:*:*:*:* 3

Related : CVE

  Date Alert Description
7.5 2022-05-16 CVE-2022-29588

Konica Minolta bizhub MFP devices before 2022-04-14 use cleartext password storage for the /var/log/nginx/html/ADMINPASS and /etc/shadow files.

4 2022-05-16 CVE-2022-29587

Konica Minolta bizhub MFP devices before 2022-04-14 have an internal Chromium browser that executes with root (aka superuser) access privileges.

7.4 2022-05-16 CVE-2022-29586

Konica Minolta bizhub MFP devices before 2022-04-14 allow a Sandbox Escape. An attacker must attach a keyboard to a USB port, press F12, and then escape from the kiosk mode.

6.8 2022-01-04 CVE-2021-20872

Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.

6.5 2022-01-04 CVE-2021-20871

Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.

4.6 2022-01-04 CVE-2021-20870

Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.

6.5 2022-01-04 CVE-2021-20869

Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.

4.5 2022-01-04 CVE-2021-20868

Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.

CWE : Common Weakness Enumeration

%idName
40% (2) CWE-200 Information Exposure
20% (1) CWE-755 Improper Handling of Exceptional Conditions
20% (1) CWE-522 Insufficiently Protected Credentials
20% (1) CWE-269 Improper Privilege Management