Summary
Detail | |||
---|---|---|---|
Vendor | Siemens | First view | 2017-05-10 |
Product | Simatic Cp 1243-1 Firmware | Last view | 2023-12-12 |
Version | Type | Os | |
Update | |||
Edition | |||
Language | |||
Sofware Edition | |||
Target Software | |||
Target Hardware | |||
Other |
Activity : Overall
COMMON PLATFORM ENUMERATION: Repartition per Version
CPE Name | Affected CVE |
---|---|
cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:* | 8 |
cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:-:*:*:*:*:*:*:* | 4 |
Related : CVE
Date | Alert | Description | |
---|---|---|---|
7.5 | 2023-12-12 | CVE-2023-38380 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product. |
7.5 | 2023-04-11 | CVE-2022-43768 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. |
7.5 | 2023-04-11 | CVE-2022-43767 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. |
7.5 | 2023-04-11 | CVE-2022-43716 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product. |
7.6 | 2022-07-12 | CVE-2022-34821 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V7.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V7.2), SCALANCE M804PB (All versions < V7.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V7.2), SCALANCE M812-1 ADSL-Router (Annex B) (All versions < V7.2), SCALANCE M816-1 ADSL-Router (Annex A) (All versions < V7.2), SCALANCE M816-1 ADSL-Router (Annex B) (All versions < V7.2), SCALANCE M826-2 SHDSL-Router (All versions < V7.2), SCALANCE M874-2 (All versions < V7.2), SCALANCE M874-3 (All versions < V7.2), SCALANCE M876-3 (EVDO) (All versions < V7.2), SCALANCE M876-3 (ROK) (All versions < V7.2), SCALANCE M876-4 (All versions < V7.2), SCALANCE M876-4 (EU) (All versions < V7.2), SCALANCE M876-4 (NAM) (All versions < V7.2), SCALANCE MUM853-1 (EU) (All versions < V7.2), SCALANCE MUM856-1 (EU) (All versions < V7.2), SCALANCE MUM856-1 (RoW) (All versions < V7.2), SCALANCE S615 (All versions < V7.2), SCALANCE S615 EEC (All versions < V7.2), SCALANCE SC622-2C (All versions < V2.3), SCALANCE SC622-2C (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (All versions < V2.3), SCALANCE SC626-2C (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (All versions < V2.3), SCALANCE SC632-2C (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (All versions < V2.3), SCALANCE SC636-2C (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (All versions < V2.3), SCALANCE SC642-2C (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (All versions < V2.3), SCALANCE SC646-2C (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (All versions), SCALANCE WAM766-1 (EU) (All versions), SCALANCE WAM766-1 (US) (All versions), SCALANCE WAM766-1 EEC (EU) (All versions), SCALANCE WAM766-1 EEC (US) (All versions), SCALANCE WUM763-1 (All versions), SCALANCE WUM763-1 (All versions), SCALANCE WUM766-1 (EU) (All versions), SCALANCE WUM766-1 (US) (All versions), SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges. |
8.4 | 2022-07-12 | CVE-2022-34820 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges. |
10 | 2022-07-12 | CVE-2022-34819 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device. |
6.5 | 2017-05-11 | CVE-2017-2681 | Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. |
6.5 | 2017-05-10 | CVE-2017-2680 | Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. |
CWE : Common Weakness Enumeration
% | id | Name |
---|---|---|
25% (2) | CWE-400 | Uncontrolled Resource Consumption ('Resource Exhaustion') |
12% (1) | CWE-770 | Allocation of Resources Without Limits or Throttling |
12% (1) | CWE-416 | Use After Free |
12% (1) | CWE-401 | Failure to Release Memory Before Removing Last Reference ('Memory L... |
12% (1) | CWE-122 | Heap-based Buffer Overflow |
12% (1) | CWE-116 | Improper Encoding or Escaping of Output |
12% (1) | CWE-94 | Failure to Control Generation of Code ('Code Injection') |