This CPE summary could be partial or incomplete. Please contact us for a detailed listing.

Summary

Detail
Vendor Siemens First view 2013-06-14
Product Wincc Last view 2023-06-13
Version 7.2 Type Application
Update *  
Edition *  
Language *  
Sofware Edition *  
Target Software *  
Target Hardware *  
Other *  
 
CPE Product cpe:2.3:a:siemens:wincc

Activity : Overall

Related : CVE

  Date Alert Description
7.8 2023-06-13 CVE-2023-30897

A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation.

This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

8.2 2017-08-30 CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.

6.8 2015-04-08 CVE-2015-2823

Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.

4.3 2015-04-08 CVE-2015-2822

Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.

6.8 2014-07-24 CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.

4.6 2014-07-24 CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.

6 2014-07-24 CVE-2014-4684

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.

4.9 2014-07-24 CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.

5 2014-07-24 CVE-2014-4682

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.

4 2013-06-14 CVE-2013-3959

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.

7.5 2013-06-14 CVE-2013-3958

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.

7.5 2013-06-14 CVE-2013-3957

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

CWE : Common Weakness Enumeration

%idName
27% (3) CWE-264 Permissions, Privileges, and Access Controls
18% (2) CWE-200 Information Exposure
9% (1) CWE-732 Incorrect Permission Assignment for Critical Resource
9% (1) CWE-611 Information Leak Through XML External Entity File Disclosure
9% (1) CWE-287 Improper Authentication
9% (1) CWE-255 Credentials Management
9% (1) CWE-89 Improper Sanitization of Special Elements used in an SQL Command ('...
9% (1) CWE-20 Improper Input Validation

Information Assurance Vulnerability Management (IAVM)

id Description
2015-B-0046 Multiple Vulnerabilities in Siemens SIMATIC Products
Severity: Category I - VMSKEY: V0059903